KE57613-C, Roger's Williamson Output Transformer
has the following design parameters:
Primary windings (50W):
- 2X115V@15Hz (Imax=0.22A)
Secondary winding:
- U0=6.5V, Imax=5A
Miscellaneous data:
Dimensions/Weight: 52X100mm/1kg
Total primary inductance: 80H@5V/50Hz (95H@10V/50Hz)
Leakage inductance: 47mH (42kHz@KT66 p-p drive)
Total primary DC resistance: 200Ohm
Maximum power input: 50W@230V/15Hz
Inductance vs DC unbalance: 67H@+/-5mA (33H@+/-20mA)
Which makes the transformer useful as for
instance:
- Standard Williamson OPT using push-pull KT66/807/6L6GC/EL34 drive with
8Ohm speaker load only (15Wsin@807).
- Boosted Williamson OPT using push-pull KT88/6550/PX25/300B drive with
4-8Ohm load (Psqr@6550>30W, +/-30% Class AB if biased@6R).
- Custom tapping at outermost secondary may however also be used but is not
recommended.
- May also even be used as mains isolation transformer for f.i tube preamps
(<230V@0.2A, 13V@0A)
- Low cost alternative: 75USD
KE57613-C, Taps
KE57613-C, Primary inductance vs push-pull voltage
KE57613-C, Primary inductance vs DC unbalance
KE57613-C,
Primary stepresponse
|