Output
Transformers KE57613-C
Primary inductance vs push-pull
voltage |
|
KE57613-C, Primary inductance vs push-pull
voltage |
|
|
|
|
|
Total primary inductance was actually
determined by measuring the secondary inductance and then multiply it
with the turn ratio squared. Imposed secondary voltage was then
multiplied with the turn ratio, thereby yielding the primary voltage.
Optional L(U(f)) dependency may be determined by regarding the fact that
the mmf is proportional to the magnetizing current and thereby inversely
reactance dependent at a certain fixed voltage. The voltage dependency